Skip to product information
1 of 3

Darkglass

Microtubes X 900

Microtubes X 900

Regular price $1,499.99 USD
Regular price Sale price $1,499.99 USD
Sale Sold out
Shipping calculated at checkout.

Designed after the revered X series pedals, the Microtubes X 900 sets a new standard for accuracy and control. We packed an all-analog preamp, a 900-watt Class D amplifier, and an ultra-quiet 6-band graphic equalizer inside to sculpt tones from crystal clear to aggressive and overdriven.

  • 900W bass amplifier in a compact format
  • Parallel compression and distortion with an adjustable frequency crossover
  • Allows users to select exactly what frequencies they want to compress and saturate
  • Built around the Microtubes X preamp voicing and controls
  • Studio quality 6-band graphic EQ
  • Built-in cab sim with 3 user-swappable IRs
  • MIDI for channel switching and muting programmability
View full details

Uncompromised Precision.

Packed with a Class D 900-watt amplifier and an ultra-quiet 6-band graphic equalizer that can sculpt the tone from aggressive and overdriven to crystal clear clean to suit everyone’s needs. The X distortion circuit allows users to select exactly what frequencies they want to compress and saturate for the low and treble, respectively.

  • Darkglass-Microtubes-X-900-Card-1

    X

    Use this push-button to turn on or off the Microtubes X Engine which allows you to compress and distort your bass signal in two separate bands, solidifying the clean low end and distorting the highs to taste from articulate to aggressive. The Microtubes X Engine operates before the EQ section.

  • Darkglass-Microtubes-X-900-Card-2

    COMP

    Controls the amount of compression for the low band when X is activated. Both threshold and makeup gain are controlled to maintain a constant level. This control is also used to control the amount of compression when the compressor is enabled for the clean signal. The clean comp is full-range.

  • Darkglass-Microtubes-X-900-Card-3

    DARKGLASS SUITE

    The Microtubes X 900 connects seamlessly with the Darkglass Suite via USB, allowing users to load impulse responses, configure MIDI settings, and fine-tune the onboard compressor and cab sim features.

1 of 3
Video thumbnail
  • Input

    Use this jack to connect your instrument via a standard ¼” mono cable.

  • Passive/Active

    Use this push-button switch to change from passive to active mode. If your bass is active it can have a hotter signal, making the amp distort earlier (feel free to use if such additional distortion is desired).

  • X

    Use this push-button to turn on or off the Microtubes X Engine which allows you to compress and distort your bass signal in two separate bands, solidifying the clean low end and distorting the highs to taste from articulate to aggressive. The Microtubes X Engine operates before the EQ section.

  • Clean Comp

    Use this push-button switch to activate the compressor circuit for the clean channel.

  • Vol (Clean Comp)

    Sets the level of the clean channel when the compressor is engaged.

  • HPF (High Pass Filter)

    Controls the cutoff frequency of the high pass filter which is applied before the clean signal is fed to the distortion circuit. Ranging from 100 Hz (for thicker, fuzzier saturation) to 1 kHz (for ultra-sharp definition).

  • Drive

    Sets the amount of distortion for the high pass side.

  • Mix

    Controls the blend between the compressed lows and the distorted highs.

  • LPF (Low Pass Filter)

    Controls the cut-off frequency of the low pass filter which is applied before the clean signal is fed to the compression circuit. Ranging from 50 Hz (for only sub-bass) to 500 Hz (to preserve some clean mids).

  • Comp

    Controls the amount of compression for the low band when X is activated. Both threshold and makeup gain are controlled to maintain a constant level. This control is also used to control the amount of compression when the compressor is enabled for the clean signal. The clean comp is full-range.

  • Level

    Sets the output volume of the X channel.

  • Bass

    +-12 dB @ 80 Hz.

  • Mids

    +-12 dB at 250, 500, 1.5k and 3 kHz.

  • Treble

    +-12 dB @ 5 kHz.

  • Master

    Sets the overall volume of the unit.

  • Mute

    Use this push-button to mute the amplifier.

  • Dimensions

    Width: 26.7 cm /10¼”
    Length: 25.5 cm / 10″
    Height: 7.1 cm / 2¾”
    Weight: 2.4 kg / 5.3 lb

  • AC Power ON/OFF

    Use this switch to release the audio energy from your bass.

1 of 18
  • Speaker Output

    Use this connector to connect the amplifier to your cabinet. This speakON combo jack allows for either speakON or ¼” speaker cable operation. The outputs are connected in parallel with the minimum load of 2,5 Ω.
    WARNING: Do not use an instrument cable with this jack. Using an instrument cable can damage your amplifier.

  • Send

    Use this output to send the signal to effects units.

  • Return

    Use this input to receive the signal from effects units. Master volume control is after this input.

  • Ground Lift

    Use this control to lift the ground of the DI XLR outputs. If you are experiencing ground noise in your DI signal try changing the setting of this control.

  • Pre DI Output

    Use this connector to send a balanced copy of your clean signal to the console, mic preamp, interface, etc.

  • Post DI Output

    Use this connector to connect the Microtubes X 900 preamplifier to balanced equipment (mic preamp, recorder, compressor, audio interface, etc.) via a standard XLR connector. Using this connection you have a signal processed by the preamp section of the amp (gain, distortion, compressor, EQ, cab sim, etc.).

  • USB

    The USB-C connector allows you to use the Darkglass Suite to load different cabinet impulses or change different parameters on your amp (MIDI; compressor on/off, etc.).

  • Headphone Output

    Connect your headphones and enjoy the processed signal chain with the impulse response cabinet emulation.

  • Headphone Volume

    Controls the volume of the headphone output.

  • Aux In

    Connect this to the headphone output of your laptop, cellphone, MP3 player, etc. The Aux In signal is fed only to the headphone output.

  • Cab Select

    Switch between 3 different cabinet impulses or bypass this section for a rawer sound.

  • MIDI

    The MIDI input allows you to control the channels of the amp via a MIDI standard controller. MIDI PC and CC can be configured in the Suite.

  • Footswitch

    The Intelligent Footswitch is a proprietary digitally controlled device that allows you to remotely engage and disengage the X Engine or to mute the amplifier. Plugging in the footswitch disables all front panel buttons except the passive/active switch and the clean comp push-button which will remain operational for the clean channel.

  • Using the Footswitch

    When using the Super Intelligent Footswitch, disengage the Clean Comp button on the front panel as the clean comp on/off will be controlled by the footswitch.

    · You can use a regular mono instrument cable to connect the amplifier to the footswitch.

    · You must remove the cable from the footswitch jack in the rear panel if you want to control the amp from the front panel.

  • Fan

    The fan forces air inside the amp to help the heatsink system cool the amp. The fan will speed up when the temperature rises to help cool the system more efficiently while keeping the noise at minimum. Be sure to never cover the vent holes.

  • AC Socket

    Use this connector to feed electric power to the amp. The X 900 has an automatically switching power supply that supports 100-240 VAC at 50/60 Hz.

1 of 16

Darkglass Suite

Using the desktop version of the Darkglass Suite allows you to select and use any of our available impulse responses from our provided library in addition to loading your own custom impulse responses. In addition, you can control the amplifier channel settings for the Super Intelligent Footswitch.

Darkglass-Intelligent-Footswitch

One Switch. Total Command.

The Intelligent Footswitch is an intuitive yet versatile accessory for your Microtubes X 900. One tap will engage and disengage the Distortion, while holding for 3 seconds will Mute the amplifier. It is connected to the head via a standard 1/4″ cable and it’s powered by a microcontroller that sends commands to the head using a proprietary communication protocol.

See the Intelligent Footswitch

SUPPORT + DOCUMENTATION

DISCLAIMER

In the interest of continuous improvement, specifications are subject to change without notice. If you have any questions, please don’t hesitate to contact us at www.darkglass.com

The manufacturer claims that the above product fulfills the requirements as set by EN55013, EN55020, EN60555-2, EN60555-3, RoHS, WEEE.